Cold Roof Constructions - Duo-pitched roofs, more than 15°
Duo-pitched roofs, more than 15° roof pitch with a high resistance underlay installed. Insulation at ceiling level.
Requirement:
Eaves ventilation equivalent to 10mm continuous opening (on opposite pitches), and ridge ventilation with a continuous opening equal to 5mm at each side of ridge.
Decra Solution:
i) DecraVent 10mm Eaves Packs, each pack providing ventilation for 6 metres of eaves, installed to provide continuous ventilation to both eaves.
Alternatively: Tile vents at appropriate
centres to provide equivalent of a 10mm
continuous opening.
ii) Decra Universal Ridge/Hip Ventilator (all Decra tile profiles) or DecraVent D Ridge system (Decra Classic, Elegance, Parctile, only) providing continuous ridge ventilation.
Alternatively: Tile vents at appropriate centres to provide equivalent of a 5mm continuous opening