Decra Roofing Resource Centre, over 30 year’s experience of finding the right lightweight roofing solutions
Print

Decra Oberon Ventilated Monopitch Ridges


Decra Oberon - Monopitch Ridge using Ridge/Barge Cap and Universal Ridge/Hip Ventilator - Detail from drawing DPTE039

 

 

Installation Guidance - Decra Oberon

1. Cut roofing felt min. 10mm short to allow clear ventilation through to ridge.

 

 


 

Universal ridge ventilator

2. Create fixing position for Ridge/Barge Cap:

  • Fix battens to top of ridge fascia sized to span from back edge of fascia to top
    edge of top tiling batten.
  • Fix 50 x 25mm batten to top of of ridge fascia board and a 38mm x 19mm batten fixed to outer face of ridge fascia board.
  • Form upstand at back edge of tile.
  • Install Universal Vent strips in front of the tile upstand and also behind the front edge of the Ridge Cap
  • Fold Ridge/Barge Cap to form monopitch ridge profile capping.

 

 

3. The Ridge/Barge caps have a slight taper in their design. Place the wider end of the ridge over the narrower end of the ridge beneath (overlap areas shown shaded grey).

Each Ridge/Barge cap should be secured with 2 nails on each side of the ridge cap through the pre-drilled holes

 

NOTE: Decra Oberon Ridge/Barge Caps are tapered to allow for laps.


NOTE: Where roof pitches exceed 35° it may be necessary to adjust the return angle of the downturned leg of theRidge/Barge Cap and use an alternative size of ridge fixing batten.

 

 

 

 

 

 

 