Ridge Course D Ridge With Universal D Ridge Vent
Universal ridge ventilator
Cut underlay short of ridge line and fit two tile battens either side of ridge, leaving a sufficient gap for ventilation.
Fit two tile battens either side of ridge.
Cut top tiles to suit (leaving a 10mm gap between the top cut edge of the tile and the top cut edge of the tile on the other side of the ridgeline).
Fix additional 50mm x 25mm batten to suit D Ridge on top of the tiles, taking care to sandwich the D Ridge Sealing Strip between the batten and the tile.
Place ridge cap into position over the top batten and the upstand edge of tile. Pull bottom edge of ridge cap away from the upstand edge of tiles and slip Universal 'D' ridge/hip ventilators into position on each side of the 'D' ridge cap. Ventilators should run continuously along each side of the ridge cap.
The ridge cap and ventilator to be nailed through the downturn of the ridge cap into the face of the batten, using four Decra fixing nails on each side. Tips on cutting and bending tiles
|